Utax CD 1015 Service Manual Page 135

  • Download
  • Add to my manuals
  • Print
  • Page
    / 296
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 134
2AV/X
1-4-87
1-4
Maintenance
Description
item No.
U251 Checking/clearing the maintenance count
Description
Displays, clears and changes the maintenance count.
Purpose
To check the maintenance count. Also to clear the count during maintenance service.
Method
1. Press the start key.
2. Select the item by lighting a copy exposure indicator using the copy exposure adjustment keys.
Copy exposure indicator Description Setting range Initial setting
Exp. 1 First 3 digits 000 to 999 000
Exp. 2 Last 3 digits 000 to 999 000
Exp. 3 Clearing the count
Clearing
1. Light exp. 3.
2. Press the start key. The count is cleared, and the indication for selecting a maintenance item No. appears.
Setting
1. Change the count using the numeric or zoom +/– keys.
2. Press the start key. The count is set, and the indication for selecting a maintenance item No. appears.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The indication for selecting
a maintenance item No. appears.
U252 Setting the destination
Description
Switches the operations and screens of the machine according to the destination.
Purpose
To be executed after replacing the backup RAM on the main PCB or initializing the backup RAM by running
maintenance item U020, in order to return the setting to the value before replacement or initialization.
Method
Press the start key.
Setting
1. Select the destination using the zoom +/– keys.
Display Description
JPn Metric (Japan) specifications
Inc Inch (North America) specifications
EUP Metric (Europe) specifications
ASA Metric (Asia Pacific) specifications
2. Press the start key. The setting is set, and the machine automatically returns to the same status as when
the power is turned on.
Completion
To exit this maintenance item without changing the current count, press the stop/clear key. The indication for
selecting a maintenance item No. appears.
Supplement
The specified initial settings are provided according to the destinations in the maintenance items below. To
change the initial settings in those items, be sure to run maintenance item U021 after changing the destination.
• Initial setting according to the destinations
Maintenance
Title Japan Inch
Europe Metric,
item No. Asia Pacific
253 Switching between double and Single Double Double
single counts
255 Setting auto clear time 120 s 90 s 90 s
348 Setting the copy density Normal Special area Special area
adjustment range